KALVIS K-2-20 20kW solid fuel boiler

KALVIS K-2-20 N 20 kW solid fuel central heating boiler
KALVIS K-2-20 N is a Lithuanian-manufactured multipurpose 20 kW bottom-combustion solid fuel heating boiler intended for central heating systems in private houses, utility buildings and other properties. Designed for manual firing, it combines a spacious combustion chamber, durable steel construction and mechanical temperature regulation. The boiler can also be adapted for the optional installation of a pellet burner if the heating system is to be modernised for automatic fuel feeding in the future.
The boiler has a nominal heat output of 20 kW, while the manufacturer specifies 82% efficiency when burning wood logs. The indicative heated area is 172–420 m² for B-class buildings and 92–220 m² for C-class buildings. These figures are guidelines rather than guaranteed heating coverage, as actual heat demand depends on building insulation, ventilation, heating system operating temperature and calculated building heat losses.
The boiler has a large 136-litre combustion chamber suitable for wood logs up to 40 cm long. Fuel may be loaded from the front or the top. In addition to wood logs, the manufacturer permits hard coal, pieces of wood waste, sawdust briquettes and peat briquettes. One fuel load can provide a combustion duration of up to 10–14 hours under suitable conditions, although actual burning time depends on the fuel quality, moisture content, chimney draught and building heating demand.
The boiler's internal walls are made from 6 mm thick steel. Its construction includes secondary air supply and a secondary combustion chamber with a refractory concrete catalyst, helping improve the combustion process. Equipment includes smoke removal, ignition and draught dampers, a fire grate shaking mechanism, ash drawer and mechanical draught regulator. The heat exchanger can be cleaned from both sides of the boiler, and safety provisions include an emergency cooling coil and the possibility of installing an optional smoke exhauster.
The KALVIS K-2-20 N has a 72-litre water capacity, a Ø 160 mm flue connection and a minimum required chimney draught of 19 Pa. Its overall dimensions are 1350 × 770 × 1210 mm (height × width × depth), and its approximate gross weight is 360 kg. The manufacturer provides a four-year warranty on the boiler body, subject to warranty conditions. Installation must include a suitable chimney, heating system safety devices and return temperature protection to prevent condensation inside the boiler.
Technical information
| General information | |
| Manufacturer | KALVIS, Lithuania |
| Model | K-2-20 N (manufacturer designation K-2-20) |
| Boiler type | Multipurpose solid fuel central heating boiler |
| Combustion principle | Bottom combustion, manual firing |
| Output and fuel | |
| Nominal heat output | 20 kW |
| Efficiency when burning wood logs | 82% |
| Primary fuel | Wood logs |
| Other permitted fuels | Hard coal, wood waste, sawdust and peat briquettes |
| Combustion chamber volume | 136 l |
| Burning duration per fuel load | Up to 10–14 hours |
| Maximum wood log length | 40 cm |
| Heated area, B / C-class buildings | 172–420 / 92–220 m² (indicative) |
| Construction and dimensions | |
| Boiler water volume | 72 l |
| Flue connection | Ø 160 mm |
| Minimum chimney draught | 19 Pa |
| Dimensions (H × W × D) | 1350 × 770 × 1210 mm |
| Gross weight (±10%) | 360 kg |
| Internal steel wall thickness | 6 mm |
| Temperature regulation | Automatic via mechanical draught regulator |
| Boiler equipment | Secondary air supply, cooling coil, dampers, fire grate shaker, ash drawer |
| Optional equipment | Pellet burner or smoke exhauster installation |
| Boiler body warranty | 4 years |
- Select boiler output according to calculated building heat losses rather than heated floor area alone.
- Have installation, chimney connection and safety system arrangements completed by a qualified heating specialist.
- Use dry logs up to 40 cm long; the manufacturer does not recommend wood with moisture above 25%.
- Regularly clean the heat exchanger, fire grates and ash drawer, and provide adequate condensation protection.

1. Room el. heating elements
2. Cooling coil
3. Smoke shut-off valve
4. Start valve
5. Flue and flue damper
6. Installation location of the smoke exhaust
7. Secondary air intake
8. Soot cleaning caps
9. Combustion chamber bricks
10. Ash drawer
11. Grid shaking mechanism
12. Grid
13. Traction control