To confirm the delivery cost before placing your order, please email us at [email protected] .
Up to 10-15 kg per parcel


TOP SANTEHNIKA.LV official dealer:


* ESTO only in Estonia, Latvia, Lithuania
Tecnosystemi SCD300079 Condensate Drain Pan for Outdoor Unit, 850 × 400 mm, 6 m Heating Cable, Anthracite

Tecnosystemi BLUE RIVER SCD300079 condensate drain pan for outdoor unit, 850 × 400 mm, 6 m heating cable, anthracite
Tecnosystemi BLUE RIVER SCD300079 is a high-quality condensate collection pan with an integrated heating cable, designed for air conditioner and air-to-air heat pump outdoor units. Its purpose is to collect water produced during outdoor unit operation and defrosting and direct it towards a controlled drainage point. The pan measures 850 × 400 mm, while its anthracite grey RAL 7016 colour coordinates with contemporary dark-coloured outdoor units, mounting brackets and building façades.
This model includes a 6-metre heating cable in a 3 + 3 m configuration, with a specific heating output of 15 W/m. Heating helps reduce the risk of condensate freezing in the pan and drainage section at low outdoor temperatures. A built-in thermal sensor controls the heating element and activates it at approximately +3 °C. The cable operates on a 230 V supply and has a 6 mm diameter. Based on the manufacturer's specifications of 6 m and 15 W/m, its calculated total nominal heating output is 90 W.
The BLUE RIVER pan body is manufactured from durable ABS + PMMA plastic with an anthracite grey finish. Its construction includes adjustable PA6 mounting brackets to accommodate suitable outdoor unit installation configurations. The manufacturer's technical drawing specifies dimensions of A = 850 mm, B = 400 mm, C = 130 mm, D = 320–680 mm and E = 85 mm. Before purchasing, check that the outdoor unit dimensions, bracket positioning and available installation space match these parameters.
Unlike a basic condensate collection pan, this model also includes a 3 m insulated condensate drain pipe, a Ø 20 mm drain connection and a pipe securing clamp. These components help guide water away from the outdoor unit and reduce uncontrolled dripping beneath the equipment. The heated drainage arrangement is particularly useful for heat pumps operating in cold weather, when automatic outdoor heat exchanger defrost cycles can generate substantial quantities of water.
Tecnosystemi SCD300079 is a practical accessory for a carefully planned heat pump or air conditioning outdoor unit installation, especially where controlled winter condensate drainage is important. The pan helps direct defrost water to an intended drainage point, while the temperature-controlled heating cable reduces the likelihood of ice formation. For safe and reliable operation, the drain pipe must be installed with an appropriate slope, electrical connections must comply with the manufacturer's instructions, and the drainage path must remain unobstructed.
Technical information
| General information | |
| Manufacturer | Tecnosystemi, Italy |
| Series | BLUE RIVER |
| Product code | SCD300079 |
| Product type | Heated condensate drain pan |
| Application | Air conditioner and heat pump outdoor units |
| Material and dimensions | |
| Body material | ABS + PMMA plastic |
| Colour / RAL | Anthracite grey / RAL 7016 |
| Pan dimensions A × B | 850 × 400 mm |
| Drawing dimensions C / E | 130 / 85 mm |
| Adjustment dimension D | 320–680 mm |
| Mounting brackets | Adjustable, PA6 material |
| Heating and electrical connection | |
| Heating cable length | 6 m (3 + 3 m) |
| Specific heating output | 15 W/m |
| Calculated nominal heating output | 90 W |
| Supply voltage | 230 V |
| Cable diameter | 6 mm |
| Heating activation temperature | +3 °C |
| Temperature control | Built-in thermal sensor |
| Resistance tolerance | −5% / +10% |
| Condensate drainage | |
| Drain connection | Ø 20 mm |
| Insulated drain pipe length | 3 m |
| Drain pipe securing | Fixing clamp |
- Check the pan dimensions and adjustable bracket compatibility with the intended outdoor unit before purchasing.
- Install the condensate drain with a suitable slope and ensure unobstructed water drainage during winter.
- Connect the 230 V heating cable according to the manufacturer's instructions and applicable electrical safety requirements.
- Periodically inspect the pan and drain for blockages and verify that the heating cable is not mechanically damaged.