Tecnosystemi SCD300068 Condensate Drain Pan for Outdoor Unit, 850 × 400 mm, 3 m Heating Cable, White

Tecnosystemi BLUE RIVER SCD300068 condensate drain pan for outdoor unit, 850 × 400 mm, 3 m heating cable, ivory
Tecnosystemi BLUE RIVER SCD300068 is a high-quality heated condensate collection pan designed for air conditioning and heat pump outdoor units. Its main purpose is to collect water produced during normal operation and defrost cycles and direct it towards a designated drainage point. The pan measures 850 × 400 mm and features an elegant ivory-coloured finish. It helps create a neat outdoor unit installation by reducing uncontrolled condensate dripping below the equipment and allowing the collected water to be drained in an organised manner.
The model is equipped with a 3-metre heating cable providing a specific heating output of 15 W/m. The heating element helps reduce the risk of water freezing and ice accumulating in the condensate collection area during cold weather. The cable operates from a 230 V AC, 50 Hz power supply and incorporates a built-in thermal sensor that automatically activates heating at approximately +3 °C. Its calculated nominal heating output is 45 W, and the cable diameter is 6 mm. Automatic temperature control allows the heating function to respond to outdoor temperature conditions without requiring routine manual switching.
The BLUE RIVER pan body is manufactured from ABS + PMMA plastic in a construction intended for outdoor installations. The product includes adjustable PA6 mounting brackets and securing components that allow the pan to fit different suitable outdoor unit supports. According to the manufacturer's technical drawing, the dimensions are A = 850 mm, B = 400 mm, C = 130 mm, D = 320–680 mm and E = 85 mm. The adjustment range provides installation flexibility; however, the specific outdoor unit and supporting bracket dimensions must be checked before purchasing.
For condensate removal, the manufacturer specifies a Ø16 mm drain pipe connection for this 3 m heating cable version. A suitable drainage pipe can therefore be attached to direct water away from the outdoor unit and surrounding building structures. Effective drainage is particularly important for heat pumps that periodically defrost the outdoor heat exchanger while operating in heating mode. These cycles can generate considerable quantities of water, and the heated pan helps reduce the possibility of freezing. The drainage pipe, its slope and any additional frost protection must be selected according to local installation conditions.
Tecnosystemi SCD300068 is a practical solution for collecting and draining condensate below a compatible heat pump or air conditioner outdoor unit. Its light colour complements white and light-coloured building façades, while the adjustable mounting system makes it easier to adapt the installation. Importantly, this product code designates the 3 m heating cable version; the 6 m cable configuration is a different model. Installation must provide stable support, a safe electrical connection, unobstructed water drainage and convenient access for regular drain cleaning and maintenance.
Technical information
| General information | |
| Manufacturer | Tecnosystemi, Italy |
| Series | BLUE RIVER |
| Product code | SCD300068 |
| Product type | Heated condensate collection pan |
| Application | Air conditioner and heat pump outdoor units |
| Material and dimensions | |
| Body material | ABS + PMMA plastic |
| Colour | Ivory |
| Pan dimensions A × B | 850 × 400 mm |
| Drawing dimensions C / E | 130 / 85 mm |
| Adjustment range D | 320–680 mm |
| Adjustable bracket material | PA6 |
| Heating and electrical connection | |
| Heating cable length | 3 m |
| Specific heating output | 15 W/m |
| Calculated nominal output | 45 W |
| Supply voltage and frequency | 230 V AC, 50 Hz |
| Cable diameter | 6 mm |
| Heating activation temperature | +3 °C |
| Temperature control | Built-in thermal sensor |
| Resistance tolerance | −5% / +10% |
| Condensate drainage | |
| Drain pipe connection | Ø 16 mm |
| Drainage arrangement | Controlled condensate discharge through a connected pipe |
| Product configuration | 3 m heating cable, without the additional insulated drain pipe kit of the 6 m version |
- Compare the pan dimensions and bracket adjustment range with the intended outdoor unit before purchasing.
- Install the condensate drain pipe with a suitable slope and protect exposed sections against freezing.
- Connect the heating cable to the electrical supply according to the manufacturer's instructions and electrical safety requirements.
- Clean the pan and drain regularly and inspect the heating cable and temperature control for correct operation.